Sign In | Join Free | My burrillandco.com
Home > ISO 8 Clean Room >

FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H

    Buy cheap FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H from wholesalers
     
    Buy cheap FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H from wholesalers
    • Buy cheap FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H from wholesalers
    • Buy cheap FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H from wholesalers

    FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H

    Ask Lasest Price
    Brand Name : anlaitech
    Model Number : AL-MODULAR CLEAN ROOM
    Certification : CE , FAT, CLASS REPORT
    Payment Terms : L/C, T/T, Western Union
    Delivery Time : 12WORKING DAYS.
    • Product Details
    • Company Profile

    FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H

    Modular Clean Room Lab Factory Dust Free Cleanroom iso 8 Clean class room


    Modular Cleanroom Information


    Keep your tests, tools, or products free from contamination. Our FDA/USDA compliant clean room partitions are perfect for compounding labs, laboratories, medical devices, and pharmaceutical packaging.


    We can personalize these clean room partitioning systems to be the precise specifications that you need.


    We also offer optional finishes, including baked-on acrylic painted 24 gauge galvanized steel, fiberglass reinforced plastic, high-pressure laminated finishes, and more.


    Roof-loading options save you valuable floor space.


    Custom pass-throughs can be built to your specifications


    Plenum Walls


    Save on design, construction, and maintenance.

    Clean room ISO Class and Airflow
    The lower your ISO class, the more frequently air needs to pass through the HEPA filter, which is measured in air change per hour (ACH).
    A common HVAC airflow will change the air twice or so per hour. However, in a cleanroom setting, the air needs to be cycled at least 10 times per hour.
    Air Changes Per Hour (ACH)
    ISO Class Approximate air changes per hour needed
    ISO 8: 10 to 25
    ISO 7: 30 to 50
    ISO 6: 60 to 150
    ISO 5: 150 to 250+
    Next, we use your ACH and the size of each room to calculate required airflow, measured in cubic feet per minute (CFM).

    CLEAN ROOM Specification:
    Model item
    ISO 8 CLEAN ROOM
    AL-CS4*6/C8
    AL-CS5*10/C8
    AL-CS6*12/C8
    AL-CS7*20/C8
    Size(mm)
    4000*6000*2500
    5000*10000*2500
    6000*12000*2500
    7000*20000*2500
    Material
    Framework
    Cold rolled steel /Aluminum/Stainless steel/sandwich panel
    Around
    Plexiglass,Soft curtain,Anti-static strip curtain/sandwich panel
    Clean Class Level
    10000
    10000
    10000
    10000
    HEPA filter
    Size(mm)
    610*610*69
    1220*610*69
    1220*610*69
    1220*610*69
    Efficiency(%)
    99.99
    99.99

    99.99
    99.99
    Air flow (m3/h)
    3600
    7500
    10800
    21000
    Pre filter
    Size(mm)
    Optional
    Motor Spec
    Power supply
    220V/50Hz
    220V/50Hz
    220V/50Hz
    220V/50Hz
    Noise(dB)
    62
    63
    62
    63

    Cleanroom’s ISO Class
    ISO 14644-1 determines your cleanroom’s class according to the concentration of particles of various sizes ranging from 0.1 microns to 0.5 microns.
    Today’s common ISO standard 14644-1 (ISO 5, 6, 7, 8) replaced the Federal Standard 209 classification (Class 100; Class 10,000; Class 100,000) in 1999 before being updated in 2015.
    That being said, many organizations continue to use and recognize the Class 100; Class 10,000; Class 100,000 terminology.
    Comparing ISO standard 14644-1 to Federal Standard 209:
    ISO Standard 14644-1 Federal Standard 209
    ISO 3 1
    ISO 4 10
    ISO 5 100
    ISO 6 1,000
    ISO 7 10,000
    ISO 8 100,000

    Advantages of Modular Cleanrooms Modular,


    free-standing cleanrooms have wall counterparts. Using modular rooms greatly reduces design, engineering and construction time, therefore reducing costs. Since they are not an integral part of a larger structure, modular rooms can be taken down and moved to other facilities, or even sold as an asset. Fixed wall clean rooms do not have this flexibility


    Expanding a modular cleanroom can be easily accomplished by taking off a wall and adding another module. The prefabricated design allows the room to be a different shape or made into multiple smaller rooms.


    All air handling and filtration equpment modules are built into the modular room ceiling. Hookups for electrical and plumbing are engineered in as part of the design.


    The amount of time it takes to construct a modular room is much less than constructing a permanent walled structure. It can take several months to construct a fixed wall cleanroom because of the amount of design, engineering and the various trades involved. However, a fairly sophisticated
    modular room can be constructed in a week or two. Onsite assembly of a modular cleanroom is also less disruptive tosurrounding operations in comparison to to their fixed wall counterparts


    Modular cleanroom systems offer potential tax advantages for businesses. They are not typically considered part of the building and can often be depreciated faster than built-in, fixed wall cleanrooms, tax consultants can provide specific tax advantage information.

    Quality FDA USDA Iso 8 Clean Room Modular Lab Factory Dust Free 7500m3/H for sale